2–4 day shipping
(830) 538-0991
59 terms

Commercial lighting glossary

The lighting terms you'll see on plans, spec sheets and quotes — explained in plain English.

#

0–10V dimming
The most common dimming method for commercial LED fixtures. Two low-voltage control wires carry a signal from 0 to 10 volts: 10V is full brightness and lower voltages dim the light. The dimmer or control system has to be 0–10V compatible.See also: Driver, TRIAC dimming, DALI

A

Ambient temperature rating
The hottest surrounding air temperature a fixture is designed to run in. Standard high bays are often rated around 40–50°C (104–122°F); high-temperature models go higher, such as 65°C (149°F). Exceeding the rating shortens LED and driver life.Warehouse LED lighting in Texas heat
Area lightAlso called: Shoebox light, parking lot light
A pole-mounted outdoor fixture for parking lots, roadways and large paved areas. Commercial LED area lights usually come in several light distribution types and mounting options to fit existing poles.Parking lot lighting guide See also: Full cutoff, Photocell

B

Ballast
The device that starts and regulates fluorescent, metal halide and high-pressure sodium lamps. LED fixtures use a driver instead; some LED tubes can run on an existing ballast while others bypass it.See also: Driver, Type A LED tube, Type B LED tube
Basis of design
The specific fixture named on a lighting schedule that the design is built around. An approved equal must meet or beat its performance.Spec vs. equal submittals See also: Or approved equal, Fixture schedule
Battery backupAlso called: Emergency battery pack, EM
A battery built into or added to a fixture that keeps part of its light on during a power outage — typically for at least 90 minutes — so the fixture can serve as emergency lighting.Emergency and exit lighting guide
Beam angle
How wide the cone of light from a fixture spreads, in degrees. Narrow beams push light farther down from high ceilings; wide beams spread it across lower ceilings.

C

Canopy light
A low-profile fixture mounted in or under a canopy — gas station fuel islands, drive-thrus and covered walkways. LED canopy lights are sealed for outdoor use and often fit existing openings.Gas station canopy lighting
CCT (correlated color temperature)Also called: Color temperature
How warm or cool white light looks, measured in Kelvin (K). 2700K–3000K looks warm, 3500K–4000K neutral and 5000K cool daylight.Color temperature guide See also: Kelvin, Selectable CCT and wattage, CRI
CRI (Color Rendering Index)
A 0–100 score for how accurately a light source shows colors compared with natural light. CRI 80 is standard for most commercial spaces; CRI 90+ is used where color matters, like retail, salons and healthcare.See also: CCT
Cut sheetAlso called: Spec sheet, data sheet
The manufacturer's one- or two-page document for a fixture: dimensions, wattage, lumens, options, ratings and the ordering part number. Cut sheets are the core of a submittal package.See also: Submittal

D

DALI
Digital Addressable Lighting Interface — a digital dimming and control protocol where each fixture can be addressed and controlled individually. Used in more advanced control systems.See also: 0–10V dimming
Damp location
A UL rating for fixtures that can handle moisture or condensation but not direct water — covered porches, some coolers and bathrooms. Fixtures exposed to rain or spray need a wet location rating.See also: Wet location, IP rating
DLC (DesignLights Consortium)Also called: DLC listed, DLC Premium
An organization that lists LED fixtures meeting its efficiency and quality requirements. DLC listing is often required to qualify for utility rebates. DLC Premium is the higher-performance tier.DLC vs. UL See also: UL listed
Driver
The electronics inside an LED fixture that convert line voltage to the power the LEDs need. Drivers also handle dimming. Heat is the main thing that shortens driver life.See also: Ambient temperature rating, 0–10V dimming

E

Efficacy (lumens per watt)Also called: lm/W
How much light a fixture produces for the power it uses — lumens divided by watts. Higher efficacy means more light for less energy. Many commercial LED fixtures run 130–170+ lm/W.See also: Lumen
Emergency lighting
Lighting that turns on automatically when normal power fails, lighting the path out of a building. Under NFPA 101 it's generally required to last at least 90 minutes and be tested monthly and annually.Emergency and exit lighting guide See also: Battery backup, Exit sign
ETL listed
A safety listing from Intertek, a Nationally Recognized Testing Laboratory. ETL and UL listings both show a fixture meets the same North American safety standards.See also: UL listed
Exit sign
An illuminated sign marking a required exit. Exit signs must stay lit during an outage, using a battery or emergency circuit. Combo units add emergency light heads to the sign.See also: Emergency lighting

F

Fire-rated fixture
A recessed fixture tested as part of a fire-resistance-rated ceiling assembly (often one or two hours) so it doesn't compromise the rating. The rating belongs to the assembly the fixture is listed for.Fire-rated downlights guide See also: IC-rated, Wafer light
Fixture scheduleAlso called: Lighting schedule
The table on a set of plans listing every fixture type on the job — type letter, description, manufacturer and model, lumens, color temperature, voltage, mounting and quantity notes.Spec vs. equal submittals See also: Basis of design, Submittal
Footcandle (fc)
A measure of how much light lands on a surface — one lumen per square foot. Light level recommendations for offices, warehouses and parking lots are usually given in footcandles.See also: Lux, Lumen
Full cutoff
An outdoor fixture that sends no light above horizontal — all light goes down. Full-cutoff fixtures reduce glare, light trespass and sky glow, and some local rules require them.See also: Area light, Military Lighting Overlay District

G

Glare
Excessive brightness that causes discomfort or makes it harder to see. It's controlled with lenses, shielding, mounting height and choosing the right fixture for the space.

H

High bay
A fixture for high ceilings — generally 20 feet and up — in warehouses, manufacturing, gyms and big-box retail. LED high bays come in round (UFO) and linear styles.Sizing high bay lighting See also: UFO high bay, Linear high bay, Low bay
HPS (high-pressure sodium)
An older outdoor lighting technology known for its orange-yellow color. HPS fixtures are commonly replaced with LED for better color and lower energy use.See also: Metal halide

I

IC-rated
Insulation Contact rated — a recessed fixture that can be safely covered by or touch ceiling insulation.See also: Wafer light, Fire-rated fixture
IES file
A standard photometric data file describing how a fixture distributes light. Lighting designers load IES files into software to model light levels and layouts.See also: Photometrics
IK rating
A scale from IK00 to IK10 for how much impact a fixture can withstand. IK10 is the highest — useful in gyms, schools, parking garages and other places fixtures might get hit.
IP rating
Ingress Protection rating — two digits showing protection against dust (first digit) and water (second digit). IP65 resists dust and water jets; IP66 and IP67 handle heavier water; IP69K is built for high-pressure, high-temperature wash-down.Commercial kitchen lighting See also: Wet location, Vapor tight

K

Kelvin (K)
The unit used for color temperature. Lower Kelvin looks warmer (yellowish), higher Kelvin looks cooler (bluish).See also: CCT

L

L70 (rated life)
The number of operating hours until an LED fixture's light output drops to 70% of its original level. It's the common way LED life is stated, such as L70 at 50,000 hours.See also: Lumen maintenance
Linear high bay
A rectangular high bay that spreads light in a long pattern — well suited to rack aisles, auto service bays and gyms.See also: High bay, UFO high bay
Low bay
A fixture for ceilings roughly 12–20 feet high — smaller warehouses, shops and retail.See also: High bay
Lumen (lm)
The total amount of visible light a fixture produces. Compare fixtures by lumens, not watts — LEDs make far more lumens per watt than older lamps.See also: Efficacy, Footcandle
Lumen maintenance
How well a fixture keeps its light output over time. LEDs dim gradually rather than burning out suddenly.See also: L70
Lux
The metric measure of light on a surface — one lumen per square meter. One footcandle is about 10.76 lux.See also: Footcandle

M

Metal halide (MH)
An older high-intensity lamp common in warehouses, gyms, parking lots and canopies. Metal halide fixtures take time to warm up and lose output quickly; they're commonly replaced with LED.See also: HPS, High bay
Military Lighting Overlay District (MLOD)
Zoning areas in San Antonio near military installations with outdoor lighting rules — such as limits on uplight and requirements for shielded fixtures — to protect night operations. Check with the City's Development Services Department.Parking lot lighting in San Antonio See also: Full cutoff

N

NSF-rated fixture
A fixture designed for food areas — sealed, smooth and easy to clean, with no places for grease or bacteria to collect — listed for non-food, splash or food zones.Commercial kitchen lighting See also: IP rating

O

Occupancy sensorAlso called: Motion sensor
A sensor that turns lights on or up when it detects people and off or down when the space is empty. Common types are passive infrared (PIR) and microwave.
Or approved equalAlso called: Equal, substitute
Spec language allowing a different fixture than the basis of design if it meets or beats the specified performance and the engineer or architect approves it through the submittal process.Spec vs. equal submittals See also: Basis of design, Submittal

P

PhotocellAlso called: Dusk-to-dawn sensor
A light sensor that turns outdoor fixtures on at dusk and off at dawn automatically.See also: Area light, Wall pack
PhotometricsAlso called: Photometric layout
A calculated plan showing light levels across a space or site for a proposed fixture layout. Used to confirm footcandle targets and uniformity before buying fixtures.See also: IES file, Footcandle, Uniformity

R

Retrofit kit
An LED kit that replaces the inside of an existing fixture — LEDs and driver — while keeping the housing in place, avoiding ceiling or wall work.LED retrofit vs. new fixtures

S

Selectable CCT and wattageAlso called: Field-selectable, tunable
A switch on the fixture that lets the installer choose between two or three color temperatures or wattages on site — one part number covers several options.See also: CCT
SubmittalAlso called: Submittal package
The package a contractor sends to the engineer or architect for approval before ordering: cut sheets with the configured part numbers highlighted, comparisons to the basis of design and required listings.Spec vs. equal submittals See also: Cut sheet, Or approved equal

T

TRIAC dimmingAlso called: Phase dimming, forward-phase
Dimming that works with standard wall dimmers by chopping the line-voltage waveform. Common for downlights in restaurants, offices and retail.See also: 0–10V dimming
TrofferAlso called: Flat panel, lay-in fixture
A rectangular fixture that lays into a drop (grid) ceiling, usually 2x2 or 2x4 feet. LED flat panels and troffers are standard in offices, schools and clinics.
Type A LED tubeAlso called: Plug-and-play tube
An LED tube that runs on the fixture's existing fluorescent ballast — the quickest swap, but the ballast stays and can still fail.See also: Type B LED tube, Ballast
Type B LED tubeAlso called: Ballast-bypass tube
An LED tube wired directly to line voltage with the ballast removed. It eliminates ballast failures but requires rewiring by an electrician.See also: Type A LED tube, Ballast

U

UFO high bayAlso called: Round high bay
A round, disc-shaped LED high bay that spreads light in a wide circular pattern — common in open warehouses, shops and gyms.Sizing high bay lighting See also: High bay, Linear high bay
UL listed
Tested and listed by Underwriters Laboratories to meet North American safety standards. Commercial fixtures should carry a UL or ETL listing.DLC vs. UL See also: ETL listed, DLC
Uniformity
How even light levels are across a space. Good uniformity avoids bright spots and dark gaps — especially important in parking lots and warehouses.See also: Photometrics

V

Vapor tight
A sealed, gasketed fixture that keeps out moisture and dust — used in parking garages, car washes, coolers, food processing and wash-down areas.Vapor-tight fixtures See also: IP rating, Wet location

W

Wafer lightAlso called: Canless downlight
An ultra-thin LED downlight that installs directly in the ceiling without a recessed can. Fire-rated and IC-rated versions are common in commercial work.Fire-rated downlights guide See also: IC-rated, Fire-rated fixture
Wall pack
A wall-mounted outdoor fixture for building perimeters, doors, loading docks and alleys. Full-cutoff wall packs aim light down to reduce glare.See also: Full cutoff, Photocell
Wet location
A UL rating for fixtures that can be exposed directly to rain, spray or wash-down — outdoor and wash-down areas need wet-location fixtures.See also: Damp location, IP rating
WraparoundAlso called: Wrap light
A surface-mounted linear fixture with a lens that wraps around the sides, spreading light across ceilings and walls — common in utility rooms, stairwells and back hallways.

Have a lighting schedule full of these terms?

Send it to us — we'll match every fixture, explain the options and quote it.